E-DIG-STA (Emulated Digital Line)
Issue 1 June 2005 1127
Table 383: Test #9 Digital Line NPE Crosstalk Test
Error
Code
Test
Result
Description / Recommendation
1 ABRT During testing of the primary information channel, system resources may
not have been available or the port was busy during the test.
1. Check the port status.
2. Use display port location to determine the station extension of
the port. Use status station to determine the service state of the
port. If the port is in use, wait until it is idle before retesting.
3. If the port status is idle, then retry the command at 1-minute intervals
up to 5 times.
2 ABRT During testing of DTDM, system resources may not have been available or
he port was busy during the test.
1. Check if port is being used. If possible, disconnect by toggling the
disconnect button on DTDM. Retry the command after 1 minute.
!
CAUTION:
CAUTION: This action drops the call in progress.
1000 ABRT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Use display port location to determine the station extension or
attendant number of the port. Use status station or status
attendant to determine the service state of the port. If the port is in
use, wait until it is idle before retesting. Attendants are always in use
(off-hook) if the handset is plugged in and the port is not busied out.
2. If the port status is idle, then retry the command at 1-minute intervals
up to 5 times.
1001 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABRT The system could not allocate time slots for the test. The system is under
heavy traffic conditions or has time slots out of service due to TDM-BUS
errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals up to 5 times.
1 of 2