Communication Manager Maintenance-Object Repair Procedures
1248 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
External Device Alarm Test (#120)
The External Device Alarm Test requests the state of the External Device Alarm from a
Maintenance circuit pack and reports the results. The test has no effect on the external device
itself.
Table 427: Test #120 External Device Alarm Test
Error
Code
Test
Result
Description / Recommendation
1000 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1035 ABRT The PN containing this equipment is not available.
Resolve every PN problem with this cabinet.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2. (Maintenance Board) If the test continues to ABORT with Error Code
2000, check for system powering problems with the A carrier. Resolve
every AC-POWER and CARR-POW alarm in a multi-carrier cabinet or
DC-POWER alarms in a single-carrier cabinet. Then, repeat the test.
3. (Maintenance Board) If the test continues to ABORT with a 2000 Error
Code, resolve every maintenance circuit pack error. Then, repeat the
test.
2029
2100
2319
2320
2500
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1 of 2