TIE-TRK (Analog Tie Trunk)
Issue 1 June 2005 2323
1915 ABRT Busy tone detected from far end.
1. Since the test line at the far end was busy. Try the test again.
2. If the test continues to abort, the problem is with the far-end system.
1918 ABRT Test progress tone not removed from far end (type 105 test line only).
1. The problem is with the far-end system; a technician at the far end
should test the test line (TN771 or ADFTC).
1919 ABRT Unexpected far-end release
1. The problem is with the far-end system; a technician at the far end
should test the test line (TN771 or ADFTC).
1920 ABRT No response from far end.
1. The problem is with the far-end system; a technician at the far end
should test the test line (TN771 or ADFTC).
1921 ABRT No data returned from far end.
1. The problem is with the far-end system; a technician at the far end
should test the test line (TN771 or ADFTC).
1922 ABRT Steady, unidentifiable tone from far end.
1. See actions for Error Code 1905.
1923 ABRT Broadband energy detected from far end (such as voice or
announcement).
1. See actions for Error Code 1905.
1924 ABRT No test tone from far end
1. See actions for Error Code 1905.
1938 ABRT Near-end self test failed.
1. Test the TN771 circuit packs.
1939 ABRT Loss self check at 0dBm at 1004 Hz failed.
1. Test the TN771 circuit packs.
Table 834: Test #844-848 Transmission Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 5