CO-DS1 (DS1 CO Trunk)
Issue 1 June 2005 833
S8300
/
G700
1412
ABRT This test does not execute on a G700 Media Gateway.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2012 ABRT The test was aborted due to an internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals up to 5 times.
2000 FAIL Response to the seizure message was not received within the allowable
time period.
1. Enter list configuration board location. If the circuit pack
is a TN767B vintage 8 or 9, a failure of test 314 causes a subsequent
failure of test 7 due to a firmware bug. Eventually, the board and all of
its ports will be taken out of service and extraneous on-board alarms
will be generated. Replace the circuit pack with a TN767C V3 or later.
2. Verify that the Trunk Type field on the Trunk Administration form
matches the trunk type administered on far-end switch.
3. Look for DS1-BD or UDS1-BD errors in the hardware error log. If
present, see DS1-BD (DS1 Interface Circuit Pack)
on page 978 or
UDS1-BD (UDS1 Interface Circuit Pack)
on page 2374.
4. Retry the command at 1-minute intervals up to 5 times.
2053 FAIL At least one of the following errors was found on the DS1 circuit pack:
Loss of signal (1281), Blue alarm (1793), Red alarm (2049), Yellow alarm
(2305), or Hyperactivity (1537).
1. Look for these error types in the hardware error log, and then follow
the procedures given in the maintenance documentation that is
appropriate for the error type that was found.
Table 285: Test #314 DS1 CO Dial Tone Seizure Test (continued)
Error
Code
Test
Result
Description / Recommendation