Communication Manager Maintenance-Object Repair Procedures
670 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
AXA12-BD (AUDIX Circuit Packs)
Error log entries and tests also apply to ADX8D-BD and AXD12-BD.
S8700 MC
The TN568 is an EMBEDDED AUDIX circuit pack that occupies 2 slots in a port carrier. The
tests below apply only to switch-side maintenance, which tests a circuit pack’s components
related to the TDM-bus interface. The AUDIX system has an extensive maintenance strategy of
its own that is described in EMBEDDED AUDIX System Maintenance, 585-300-110.
AXA12-BD
TN568 EMBEDDED AUDIX circuit packs operating in control-link mode appear to the system as
TN746 Analog Line circuit packs with vintage greater than 50. For circuit-pack-level problems,
see XXX-BD (Common Port Circuit Pack/Media Module)
on page 2539. The maintenance
strategy for ports on the TN568 operating in control-link mode is described in ADXCL-PT.
ADX8D-BD
TN568 EMBEDDED AUDIX circuit packs operating in 8-port digital mode appear to the system
as TN754 Digital Line circuit packs with vintage greater than 50. For circuit-pack-level
problems, see XXX-BD (Common Port Circuit Pack/Media Module)
on page 2539. The
maintenance strategy for ports on the TN568 operating in 8-port digital mode is described in
ADXDP-PT.
MO Name in
Alarm Log
Alarm
Level
Initial Command to Run Full Name of MO
AXA12-BD MIN test board location sh AUDIX circuit pack
AXA12-BD WRN test board location sh AUDIX circuit pack
ADX8D-BD MIN test board location sh AUDIX circuit pack
ADX8D-BD WRN test board location sh AUDIX circuit pack
AXD12-BD MIN test board location sh AUDIX circuit pack
AXD12-BD WRN test board location sh AUDIX circuit pack