Communication Manager Maintenance-Object Repair Procedures
2206 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
s. Error Type 3588: the board receives D-channel data from the bus faster than it can process
the data. The FIFO RAM buffers overflowed. This error occurs occasionally due to the
statistical sizing of the buffers; however, frequent occurrences may indicate a LAPD
parameter mismatch between the two endpoints of a packet-switched connection. Run the
long test sequence, and pay particular attention to the results of the Receive FIFO Overflow
test (#625).
t. Error Type (3589: the BRI Port Local LAN Loop Around test (#618) failed. Run the long test
sequence, and pay particular attention to the results of Test #618.
u. Error Type 3590: an activated BRI port receives a frame containing a DLCI over a D
channel for which it does not have a translation. This error normally indicates an off-board
problem related to a state mismatch between the far end and the switch. This error is
logged only.
v. Error Type 3591: the circuit pack received a frame containing a DLCI over the TDM
D-channel for which it does not have a translation. This error occurs only on a system that
switches the packet implementation of the D-channel over the TDM bus, and indicates an
off-board problem related to the state mismatch between the board and the packet
implementation of the TDM D-channel. This error is logged only.
w. Error Type 3592: 1the port is generating too many uplinks and is taken out of service for a
period of time.
x. Error Types 3841–3942: Table 786: Aux Data Values for Error 3841–3942
on page 2206
contains the received ISDN cause values for Errors 3841–3942 that are recorded in the
hardware error logs. Unless otherwise stated, the cause values are D-channel events. The
Aux Data field shows which port caused the error.
Table 786: Aux Data Values for Error 3841–3942
Aux Data
Value
Type of
Problem
Meaning
2 admin No route to specific transit network
3 admin No route to destination (or Germany bcap not imp)
6 admin Channel unacceptable
18 switch
problems
No user responding
38 switch
problems
Network failure
50 subscription Requested facility not subscribed
52 admin Outgoing calls barred
54 admin Incoming calls barred
1 of 2