Communication Manager Maintenance-Object Repair Procedures
1598 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1538 (m)Any MMIN
WRN
1
ON
1793 Any Blue Alarm
Inquiry (#139)
MAJ
MIN
WRN
2
OFF test board location
1794 Any Blue Alarm
Inquiry (#139)
MAJ
MIN
WRN
2
OFF test board location
1795 Any Blue Alarm
Inquiry (#139)
MAJ
MIN
WNG
2
OFF test board location
2049 Any Red Alarm
Inquiry (#140)
MIN
WRN
1
OFF test board location
2305 Any Yellow Alarm
Inquiry (#141)
MIN
WRN
1
OFF test board location
2306 Any Yellow Alarm
Inquiry (#141)
MIN
WRN
1
OFF test board location
2561 Any Major Alarm
Inquiry (#142)
MIN
WRN
1
OFF test board location
2817 Minor Alarm
Inquiry (#143)
MIN
WRN
1
OFF test board location
3073 to
3160 (n
)
Any Slip Alarm Inquiry
(#144)
MIN
WRN
1
OFF test board location r 6
3585 to
3601 (o
)
Any Misframe Alarm
Inquiry Test
(#145)
MIN
WRN
1
OFF test board location r 6
3840 (p
) Any None
3841 (q
) 4358
3842 (r
) 46097
3999 (s
) Any None
1. If ports are assigned to the Media Module, then a minor alarm is raised. If no ports are assigned to the
Media Module, then a warning alarm is raised. The alarm is raised after the Media Module has been
missing for a period of 15 minutes. Warning alarms are also raised against any ports administered on
the Media Module.
2. Major alarms on this MO may be downgraded to minor or warning alarms, and minor alarms
on this MO may be downgraded to warning alarms based on values s
et in set options.
Table 589: DS1 Interface Media Module Maintenance Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
3 of 3