Communication Manager Maintenance-Object Repair Procedures
2368 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1181 ABRT Ran out of ADM TSC resources.
1. Execute test tsc-administered at 1-minute intervals up to 3
times.
1182 ABRT The BX.25 link is down at the gateway.
1. Disable the ADM TSC.
2. Check the status of the gateway link using status link lnk#.
3. Once the gateway link indicates an in-service state, enable the
Administered TSC.
4. Execute test tsc-administered.
2000 ABRT The Administered TSC is not responding to a TSC heartbeat inquiry.
1. Retry test tsc-administered at 1-minute intervals up to 3 times.
2. If the problem continues to fail, obtain the status of the D channel or
D-channel pair associated with the ADM TSC using status
signaling-group grp#. If the D channel is INS (i.e., in-service) and
the status of the ADM TSC appears to be active, then disable and
enable the ADM TSC through administration.
NOTE: To disable the ADM TSC, display the Signaling Group
administration screen using change signaling-group grp# where
group refers to the number of the signaling group under which the
suspect TSC is administered. Set the Enable field to n. To enable the
ADM TSC, set the Enable field to y.
3. Execute test tsc-administered.
4. If the test fails, check the ADM TSC node on the other side of the
network to verify that the ADM TSC is indeed active.
2012 ABRT Internal system error.
1. Execute test tsc-administered at 1-minute intervals up to 5
times.
Table 848: Test #604 TSC Heartbeat Inquiry Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 4