Communication Manager Maintenance-Object Repair Procedures
1576 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
MET Line Station Audits Test (#61)
This is a series of three tests that are classified as audits. These audits abort if attempted on an
out-of-service station. Although this test never actually returns a fail result (except for the
internal system error), it is possible that it will enter error types 257 (over current) or 513 (open
circuit) into the error log. To determine whether there are any problems that do not show up in
the test result, look for these error types in the error log. If these errors appear in the error log or
if user complaints still exist, investigate by using other circuit pack tests and by examining the
station, the wiring, and the connections. The tests are as follows:
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use list
config and resolve any problems that are found.
2. If the board was found to be inserted correctly, enter busyout board
location.
3. Enter the reset board location command.
4. Enter the release board location command.
5. Enter test board location long.
This should re-establish the linkage between the internal ID and the port.
If this is not the case, check to ensure that there is a valid board inserted.
Table 582: Test #60 MET Line Station Lamp Updates Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2
Switchhook
Audit
This is an update of the Communication Manager records according
to the circuit packs’ records.
Bad Scan Inquiry A message is sent uplink that contains a count that is generated due
to certain events relating to the link conditions. This is an indication
of data transmission problems between the MET Line circuit pack
and the voice terminal.
EPF Inquiry The status of the Electronic Power Feed is sent uplink. Possible
conditions are: EPF-on-ok, EPF-off, EPF-no-load, and
EPF-on-overcurrent.