Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
2212 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Table 789: Test #618 BRI Port Local LAN Loop Around
Error
Code
Test
Result
Description / Recommendation
1015 ABRT The port is not out-of-service.
1. Use status bri-port location to determine the status of
the port.
2. If it is in use, wait until it is idle, and then use busyout port
location to place it in the out-of-service state and repeat this
test.
!
CAUTION:
CAUTION: Since the busyout command is destructive, execution
of this command prior to the port being idle causes
every call associated with the BRI port to be torn
down.
1139 ABRT The Packet bus in the port network is out-of-service.
1. Follow the repair procedures for the Packet bus.
2. Run test port location long and verify the repair by
viewing the results of the BRI Port Local LAN Loop-Around test
(#618).
1141 ABRT The PKT-CTRL is out-of-service.
1. Follow the repair procedures for the PKT-CTRL.
2. Run test port location long and verify the repair by
viewing the results of the BRI Port Local LAN Loop-Around test
(#618).
1144 ABRT The Processor Port Network Packet Bus is out-of-service
1. Follow the repair procedures for the Packet Bus.
2. Run the test port location long and verify the repair by
viewing the results of the BRI Port Local LAN Loop-Around test
(#618).
S8300 / G700:
1412
ABRT This test does not execute on a G700 media gateway.
2012
2100
ABRT Internal system error
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 2