DIOD-DS1 (DS1 DIOD Trunk)
Issue 1 June 2005 963
2053 ABRT At least one of the following errors is found on the DS1 circuit pack:
● 1281 – Loss of signal
● 1793 – Blue alarm
● 2049 – Red alarm
● 2305 – Yellow alarm
● 1537 – Hyperactivity
Look for the previous error types in the Hardware Error Log, and follow the
procedures given in the DS1-BD (DS1 Interface Circuit Pack)
on page 978
or UDS1-BD (UDS1 Interface Circuit Pack)
on page 2374 maintenance
documentation for the listed error types.
FAIL The trunk cannot be seized for an outgoing call.
1. Verify that the Trunk Type field on the trunk administration screen
screen matches the trunk type administered on far-end switch.
2. Look for UDS1-BD errors in Hardware Error Log. If present, see
UDS1-BD (UDS1 Interface Circuit Pack)
on page 2374.
3. Retry the test at 1-minute intervals up to 5 times.
PASS The trunk can be seized for an outgoing call.
Table 331: Test #314 DS1 CO Dial Tone Seizure Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 3