Communication Manager Maintenance-Object Repair Procedures
1716 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1004 ABRT The port was seized by a valid ISDN-PRI test call. Use list
isdn-testcall to determine which call is using the port (from the M/T
Port column). Wait for the test call to complete as indicated in the Start
Time and Duration fields of the above display, or abort the test call with
clear isdn-testcall grp#/mem# where grp#/mem# is
determined from the B-channel field of list isdn-testcall.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort and the port is idle, escalate the
problem.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the test at 1-minute intervals up to 5 times.
2100 ABRT System resources required to run this test are not available.
1. Retry the test at 1-minute intervals up to 5 times.
7 FAIL Conference test failed on the primary information channel. In most
cases, the user may not notice a disruption in service.
1. Run the circuit pack tests to check the Tone Generator circuit pack
and the Tone Detector circuit pack using test board location.
2. Resolve any problems that are detected on the Tone Generator
circuit pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are
functioning properly, and the test still fails, replace the Maintenance/
Test circuit pack.
14 FAIL The primary information channel is not transmitting properly. User
impact may range from nothing to not being able to use this port.
1. Run the circuit pack tests to check the Tone Generator circuit pack
and the Tone Detector circuit pack using test board location.
2. Resolve any problems that are detected on the Tone Generator
circuit pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are
functioning properly, and the test still fails, replace the Maintenance/
Test circuit pack.
PASS The Maintenance/Test digital port digital trunk testing capability is
operating correctly.
Table 634: Test #13 Digital Port Loop-Around Test (continued)
Error
Code
Test
Result
Description / Recommendation