STA-FWDL
Issue 1 June 2005 2125
13 Two consecutive terminals failed to download due to internal timeouts. It is
likely that all terminals will fail as well so the schedule is stopped and any
remaining terminals in the download list are aborted.
14 Could not build a list of terminals from the range specified in the change
firmware station-download form. Check the administered stations
for exact extension numbers.
15 The scheduled stop time was reached without completion of all scheduled
terminals. The status firmware station-download command
indicates all terminals not downloaded with a status of ABRT and a Reason
Code of 3 (see Table 762: Reason Codes for status firmware
station-download command on page 2126). If the Continue daily until
completed field is y, this error will not occur because the continuation
option causes the schedule to resume the next day at the scheduled start
time (see Table 761
).
Table 761: Schedule States of status firmware station-download command
State Schedule
Done?
Description
Idle No No downloads Pending or Active and there are no unresolved
errors/alarms for the last download
Pending No Download has been scheduled but not yet started. Check the
start time to see when it is scheduled to start.
Active No Download is currently active. Actively downloading terminals
should be listed with a status of ACTV. If the schedule has just
started and no downloads are listed, the system may be
waiting for a FAC requested or terminal requested download
to complete before it begins.
Resume-pending No Download was stopped at the Stop Date/Time but not all of
the terminals have been attempted. Downloading will resume
at the scheduled Start Date/Time listed on the screen.
Aborted Yes Download was aborted for the entire range of terminals. This
could happen if the firmware image was bad, damaged or
lost.
1 of 2
Table 760: Error Type 513 Aux Data descriptions (continued)
Aux
Data
Description
2 of 2