Communication Manager Maintenance-Object Repair Procedures
510 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
b. Error Type 1: the two ends of the ATM trunk do not agree on the ISDN call state. Possible
causes:
● Received a DISConnect or RELease COMplete message with cause value 52 (outgoing
calls barred)
● Received a DISConnect or RELease COMplete message with cause value 54 (incoming
calls barred)
Table 159: ATM-BCH Error Log entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a
) 0 Any Any Any test port location
1(b
) Any None test port location
18 0 busyout trunk grp/
mbr
release trunk grp/mbr
129 (c
) None WRN OFF test port location
130 (d
) test port location
257(e
) Any Service State Audit test
(#256)
test port location
513(f
) Any None WRN OFF test port location
769(g
) Any Service State Audit test
(#256)
test port location
1793
(h
)
Any None test port location
3073(i
) Any Service State Audit test
(#256)
test port location
3585(j
) Any None none
3841
(k
)