Communication Manager Maintenance-Object Repair Procedures
2064 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
106 FAIL The SNI circuit pack cannot communicate with the SNI in slot 6 over the
circuit path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 6.
Use display errors to find any SNI-BD errors and check
display alarms to see if the errors have on-board alarms. Then
follow the repair procedures for SNI-BD.
2. Use display errors to check the error log for other SNI circuit
packs with SNI-PEER Error Type 1025. If other SNI circuit packs have
SNI-PEER Error Type 1025, then replace the SNI in slot 6. Replacing
an SNI may be service interrupting. See the SNI-BD section for the
procedure for replacing an SNI.
If other SNI circuit packs do not have SNI-PEER Error Type 1025 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 6.
107 FAIL The SNI circuit pack cannot communicate with the SNI in slot 7 over the
circuit path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 7.
Use display errors to find any SNI-BD errors and check
display alarms to see if the errors have on-board alarms. Then
follow the repair procedures for SNI-BD.
2. Use display errors to check the error log for other SNI circuit
packs with SNI-PEER Error Type 1281. If other SNI circuit packs have
SNI-PEER Error Type 1281, then replace the SNI in slot 7. Replacing
an SNI may be service interrupting. See SNI-BD (SNI Circuit Pack)
on
page 2046 for the procedure for replacing an SNI.
If other SNI circuit packs do not have SNI-PEER Error Type 1281 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 7.
Table 749: TEST #755 SNI Circuit Path Test (continued)
Error
Code
Test
Result
Description / Recommendation
5 of 11