CLSFY-PT (Call Classifier Port)
Issue 1 June 2005 813
Table 279: Test #42 Tone Detection Verification Test
Error
Code
Test
Result
Description / Recommendation
none ABRT The system was not able to allocate every resource needed for this test,
OR there was an internal system error.
1 ABRT The system could not allocate every resource needed to test the tones.
1. Retry the command at 1-minute intervals up to 5 times.
1001 ABRT The system was unable to put the call classifier port in the appropriate
mode to test it.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABRT The system could not allocate time slots for the test connection. This
situation could occur when the system is heavily loaded. If the system is
not heavily loaded, use test tdm to test the TDM-BUS.
1. Retry the command at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a Tone-Clock for the test connection. This
may be caused by a heavy load on the system or by a faulted Tone-Clock.
1. Check to see if there are any alarms against the Tone-Clock in the PN
where the test aborted. If so, see TONE-BD (Tone-Clock Circuit)
on
page 2327 and TONE-PT (Tone Generator)
on page 2353 for
recommended procedures.
2. If a new Tone-Clock has been inserted, allow about 1-minute for
maintenance to run on the newly inserted circuit pack.
3. Retry the command at 1-minute intervals up to 5 times.
2000 ABRT Call classifier circuit pack’s response to the test request was not received
within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.