RDIG-STA (Remote Digital Station)
Issue 1 June 2005 1935
DIG-LINE Station Lamp Updates Test (#16)
This test lights every lamp on the terminal as specified. The lamp updates will run only if the
station is in-service. The status of the station is checked and the lamp updates are blocked from
taking place, if the station is not in the in-service state. This test does not affect the status of the
Message Waiting lamp.
PASS Electronic Power Feed test passed. The message to turn on the power to
the station was successfully sent to the port. Although this test will never
actually return a FAIL result except for the Internal system error described
above, it will log an error indicating the real results of the test.
1. Check the Error Log for any entries with Error Types 767 or 769 after
the test completes.
● If Error Type 767 appears in the Error Log, the test sensed no
problems with the power to the station. To verify that the station is
powered up correctly, run a self-test on the station and verify that
every feature button is operating.
● If Error Type 769 appears in the Error Log, this indicates some
problem with the power to the station. Check for a short in the
wiring, a damaged jack, a defective voice terminal, or an incorrect
type of terminal.
Table 710: Test #11 Digital Line Electronic Power Feed Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2
Table 711: Test #16 DIG-LINE Station Lamp Updates Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1 of 3