Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
MMI-BD
Issue 1 June 2005 1661
Table 614: Test #6 TSI Crosstalk Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error. This is an abnormal abort.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABRT The system could not allocate time slots for the test, the traffic load on the
system is very high, or the time slots are out-of-service due to TDM-BUS
errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a tone detector for the test. The system is
oversized for the number of tone detectors present, or some tone detectors
are out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5
times.
2000 ABRT Response to the test was not received from the MMI-BD circuit pack within
the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the
other ports are idle. Reset the circuit pack by issuing busyout board
location, reset board location, and release board
location.
2. If this result occurs again, replace the circuit pack.
2012 ABRT Internal system error. This is an abnormal abort.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary resources to run this test. This is an
abnormal abort.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The TSI was found to be transmitting in error. This causes noisy and
unreliable connections.
1. Replace the circuit pack.
PASS The TSI is correctly using its allocated time slots.