DIOD-DS1 (DS1 DIOD Trunk)
Issue 1 June 2005 959
1000 ABRT System resources required to run this test are not available. The port may
be in use on a valid call.
1. Use status station or status trunk to determine when the port
is available for testing.
1004 ABRT The port has been seized by a user for a valid call.
1. Use status station or status trunk to determine when the port
is available for testing.
2. Retry the command at 1-minute intervals up to 5 times.
1018 ABRT Test disabled by administration. This only applies to analog stations.
1. To enable test, use change station extension and set the Test
field to y. Run the test.
1020 ABRT The test did not run due to a previously existing error on the specific port or
a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit
pack and attempt to diagnose the previously existing error.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100 ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2053 ABRT At least one of the following errors is found on the DS1 circuit pack:
1281 – Loss of signal
1793 – Blue alarm
2049 – Red alarm
2305 – Yellow alarm
1537 – Hyperactivity
Look for the previous error types in the Hardware Error Log, and follow the
procedures given in the DS1-BD (DS1 Interface Circuit Pack)
on page 978
or UDS1-BD (UDS1 Interface Circuit Pack)
on page 2374 maintenance
documentation for the listed error types.
Table 329: Test #7 Conference Circuit Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3