Error Log Entries and Test to Clear Values
Note:
Note: The list config port-network command shows the cabinet number
associated with a PN.
Table 194: Error Log Encode Field Decoding
Field Variable Name Values Description
cAlarm Type 0
1
Alarm retired
MAJOR or MINOR alarm on any PNC component
x Fault class; see
description for
contributing
MOs
0 EAL (Expansion Archangel Link - EXP-PN) carries CCMS
messages
1 PACL (ATM-EI) carries ATM signaling commands from Call
Processing to the remote ATM-EI circuit packs
2 PNC hardware (providing connectivity of PN-to-PN or
-ATM-EI)
5 BFDL (bearer fault detection link) solely for the purpose of
detecting bearer faults
pp Port-network
number
0–63 0–2 for constraint class (this is an internal number; add 1 for
external port number)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
18 None busy PNC-DUP WRN ON release pnc-dup