Communication Manager Maintenance-Object Repair Procedures
1124 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
E-DIG-STA (Emulated Digital Line)
S8700 | 8710 / S8500
There are 4 tests in the Emulated Digital Line station maintenance test sequence and only one
test path in the test sequence. Once the test sequence begins, every test in the test sequence is
executed.
E-DIG-ST maintenance monitors and tests ports on the TN800 MAPD circuit pack and the
hardware connected to those ports for lines administered as a digital station. These include
stations with an emulated digital voice terminal and stations with an emulated digital voice
terminal and a linked data module. Stand-alone data modules and data adaptors in stand-alone
mode are not supported by the TN800 circuit pack. Circuit pack maintenance is covered by
E-DIG-BD.
Hardware Error Log Entries and
Test to Clear Values
MO Name in
Alarm Log
Alarm
Level
Initial SAT Command to Run Full Name of MO
E-DIG-ST MIN test port location l Emulated Digital Station
E-DIG-ST WRN test port location sh Emulated Digital Station
Table 382: Digital Line Error Log Entries – E-DIG-STA
Error
Type
Aux
Data
Associated
Test
Alarm
Level
On/Off
Board
Test to Clear Value
0 (a
)0Any AnyAnytest port location sh r 1
18 (b
)0 busyout port
location
WRN OFF rel port location
130 (c
)NoneWRNONtest port location sh
257 (d
) 40971 None
1537 (e
) 40968 None WRN OFF
1793 (f
) Voice and
Control Local
Loop test (#13)
MIN
WRN
1
ON test port location l r 3
1 of 2