Communication Manager Maintenance-Object Repair Procedures
1336 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1000 ABRT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Use display port location to determine the station extension
number of the port. Use status station to determine the service
state of the port. If the port is in use, wait until it is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals
up to 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS Electronic Power Feed test passed. The message to turn on the power to
the station was successfully sent to the port.
1. Although this test never actually returns a FAIL result, except for the
previous Internal system error, it logs an error if the overcurrent case is
detected by the hardware. Check the Error Log for any entries with
Error Type 257 when the test has completed.
2. If Error Type 257 does not appear in the Error Log within 10 seconds
after completion of this test, it is safe to assume that the test sensed no
problems with the power to the station. To verify that the station is
powered up correctly, run a self-test on the station, if available, and
check that every feature button is operating.
3. If Error Type 257 appears in the Error Log, this indicates some problem
with the power to the station. Check for a short in the wiring, a
damaged jack, a defective voice terminal, or an incorrect type of
terminal.
Table 466: Test #56 Hybrid Electronic Power Feed Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3