Communication Manager Maintenance-Object Repair Procedures
1264 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Configuration Audit (#759)
This test is nondestructive.
This test is run via test board short or test board long for SNI circuit packs or via
test fiber-link for fiber links with SNI endpoint(s).
This test queries the SNI for SNCs in the same switch node carrier, SNI peers, DS1 converter s,
and EI or SNI neighbors that the SNI can communicate with and compares this data to the
administered data.
Failures of this test cause entries in the error and alarm logs against Switch Node Configuration
(SN-CONF) with the board location of the SNI.
This test is unable to detect the case where an SNI is connected to the same type of board (EI
or SNI) as administered but located in a different cabinet but the same carrier and same slot as
the administered fiber endpoint. Use list fiber-link to see the administered fiber
endpoint. This test can only detect if the fiber endpoint connected to the SNI is in a different
carrier, slot location than the administered fiber endpoint.
If the SNI is connected to the same type of fiber endpoint as the administered fiber endpoint, but
the location is the same as administered except for the cabinet, no phone calls will work
correctly; some phone calls will not go through and some phone calls will ring the wrong phone.
The test led command can be used in this case to check connectivity.
1. Run test led port-network for each administered PN, and verify that the LEDs on the
correct PN are lit.
If not, check that the fiber connections to the PN are consistent with the administered fibers
(list fiber-link) that do not light the LEDs as expected.
127 FAIL The data is not correctly looped around on Endpoint 1 of the fiber link. Use
list fiber-link to display fiber link endpoints.
1. Replace the SNI circuit pack.
227 FAIL The data is not correctly looped around on Endpoint 2 of the fiber link. Use
list fiber-link to display fiber link endpoints.
1. Replace the SNI circuit pack.
PASS No problems associated with this test are detected on the SNI(s).
Table 439: Test #757 SNI Destructive Facility Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2