OPS-LINE (DS1 Off-Premises Station Line)
Issue 1 June 2005 1737
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 15: this software audit error does not indicate a hardware malfunction. Run the
short test sequence and investigate associated errors (if any).
c. Error Type 18: the DS1 OPS Line was busied out by busyout station ext. No calls
can be made on this line.
d. Error Type 130: the circuit pack was removed or was insane for more than 11 minutes. To
clear the error, reinsert or replace the circuit pack.
e. Error Type 1793 indicates a problem with the DS1 Interface circuit pack. Because there is
no error against the OPS-LINE port, no alarm is raised against the OPS-LINE port.
However, there should be errors logged against the DS1 Interface circuit pack. Look for
DS1-BD/UDS1-BD errors in the Hardware Error Log, and follow the procedures in DS1-BD
(DS1 Interface Circuit Pack) on page 978.
Table 643: DS1 OPS Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a) 0 Any Any Any test station ext
15 (b
) Any Audit and Update test
(#36)
18 (c
)0busyout station
ext
WRN OFF release station ext
130 (d
) None WRN ON test station ext
1281 Conference Circuit test
(#7)
MIN ON test station ext l r 4
1537 NPE Crosstalk test (#6) MIN ON test station ext l r 3
1793 (e
) test board location l