TBRI-PT (ISDN Trunk-Side BRI Port)
Issue 1 June 2005 2223
1 to 88 FAIL The circuit pack and the remote endpoint are not synchronized to the
same clock rate, which has generated the Slip alarm. The Error
Code equals the number of slips detected by the TN2185 circuit pack
since the last Slip Alarm Inquiry test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the circuit pack is a TN2185, enter list measurement
ds1-log location to read the error seconds measurement.
3. Verify that both endpoints of the DS1 link are administered using
the same signaling mode, framing mode, and line coding.
4. Check the physical connections of DS1 Interface circuit packs
and cable.
5. Replace the local DS1 Interface circuit pack and repeat the test.
6. Contact T1 Network Service to diagnose the remote DS1
endpoint.
PASS No Slip alarm is detected on the DS1 Interface circuit pack.
0 NO BOARD The DS1 Interface circuit pack is not administered.
1. Use add ds1 location to administer the DS1 Interface circuit
pack.
2. Run the test again.
3. If the test continues to return NO BOARD, escalate the problem.
Table 795: Test #1244 BRI Port Slip Query Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2