Communication Manager Maintenance-Object Repair Procedures
648 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1003 ABRT Could not allocate a tone receiver. Too few Tone Detectors installed or
Tone Detectors out-of-service.
1. Identify and correct any TTR-LEV (TTR Level) errors listed in the Error
Log.
2. Resolve any TONE-PT (Tone Generator) errors listed in the Error Log.
3. Retry the test up to 5 times at 1-minute intervals a maximum.
1962 ABRT Every TALKER DSP is busy.
2000 ABRT Test timed out.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate required system resources
1. Retry the command 5 times at 1-minute intervals.
2302 ABRT Inconsistent uplink message from the ATM-TRK circuit pack.
1. Retry the command up to 3 times at 1-minute intervals.
2752 ABRT The circuit pack in this location is not a TN2305A/2306A.
1–8,
None
FAIL ATM-TRK circuit pack writing on unauthorized TDM time slots. The error
code indicates the number of TALKER DSPs that are at fault. These
DSPs cannot be used again until this test of the ATM DSP test (#1293)
tells the circuit pack to use them again.
1. Retry the command up to 3 times at 1-minute intervals.
2. If the failure persists, replace the circuit pack.
1-8 PASS ATM-TRK circuit pack not talking to un-authorized time slots on the TDM
bus. The error code indicates the number of TALKER DSPs tested.
Table 221: ATM Crosstalk Test (#1298) (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2