Communication Manager Maintenance-Object Repair Procedures
1508 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
MAPD-BD (MAPD Interface Circuit Pack TN802)
S8700 | 8710 / S8500
The TN802 Multiple Application Platform (MAP-D) circuit pack allows sending voice and fax
from a Communication Manager media server through the Internet to another Communication
Manager media server also having this feature or to other PBXs that are equipped with the
Internet Telephony server (ITS-E).
Throughout this section, the term TN802 means the MAP-D IP trunk circuit pack.
Be sure to observe these special considerations for the TN802:
Port alarms on this circuit pack display as “TIE-DS1” in the Alarm and Error logs.
The reset board command reboots the MAPD PC CPU, but busyout board only
busies out every emulated port on the board.
Switch resets that take the switch out of service for more than 20 seconds also cause the
MAPD's PC to reboot, which takes several minutes to complete.
Switch-Demanded Tests
Switch-demanded diagnostic tests on the TN802 do not run unless the Internet trunking
application is running on Windows NT, located on the circuit pack.
Feature Limitations
The Internet trunking application relies on the single call scenario, or a direct, point-to-point call
that does not terminate at multiple S8700 Media Server nodes through call processing.
MO Name in
Alarm Log
Alarm
Level
Initial SAT Command to Run Full Name of MO
MAPD-BD MAJ test board location sh MAPD Interface circuit pack
MAPD-BD MIN test board location l MAPD Interface circuit pack
MAPD-BD WRN test board location sh MAPD Interface circuit pack