Communication Manager Maintenance-Object Repair Procedures
620 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
Table 208: ATM-TRK Error Log entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
00Any Any test board location
1(a
) None MIN ON
18(b
)0busyout board
location
MIN ON release board location
23(c
) 0 None MIN ON
125(d
) None MIN ON
257(e
) Any Control Channel Loop
(#52)
MIN ON test board location r
2
513(f
) Any ATM Cross Talk (#1298) MIN ON test board location l
r 1
769(g
) 35 ATM Error Query (#1259) WRN OFF test board location
770(g
) 25 ATM Error Query (#1259) WRN OFF test board location
771(h
) 26 ATM Error Query (#1259) WRN OFF test board location
1281(i
) ATM Board Error Query
(#1259)
WRN
/ MIN
OFF test board location r
1
1537(j
) 12 None WRN
/ MIN
ON
1538(k
) 0 None WRN
/ MIN
ON reset board location
1794(l
) 13 None MIN ON
2049(m
) 15 None WRN OFF test board location
2306(n
) None
2561(o
) Packet interface test
(#598)
MIN ON test board location r
2
2817(p
) 1-24 ATM Board DSP (#1293) WRN
/ MIN
ON test board location
1 of 2