Communication Manager Maintenance-Object Repair Procedures
1518 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
3. At the command prompt, type ping 10.32.64.97 (the internal IP trunk server’s address),
and press Enter.
If configured correctly, the system displays:
Reply from nnn.nn.nn.nn: bytes=32 time <##ms TTL=###
If there is no reply:
a. Check that the internal cables on the TN802 circuit pack (Notes 4 and 6 in
Figure 87: TN802 board assembly and cables (side view)
on page 1520) have not
worked loose.
b. Otherwise, replace the circuit pack.
4. At the command prompt, type ping 10.32.64.96 (the IP address of the internal Motorola
MPC860 processor), and press Enter.
If configured correctly, the system displays:
Reply from nnn.nn.nn.nn: bytes=32 time <##ms TTL=###
If there is no reply:
a. Check that the internal cables on the TN802 circuit pack (Notes 4 and 6 in
Figure 87: TN802 board assembly and cables (side view)
on page 1520) have not
worked loose.
b. Otherwise, replace the circuit pack.
5. Ping the gateway: at the command prompt, type ping XX.XXX.XXX.XXX (the IP address
of the gateway), and press Enter.
6. When finished, type exit at the command prompt, and press Enter.