Communication Manager Maintenance-Object Repair Procedures
364 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1 is an in-line error that can only be resolved over time. No terminal equipment
was present when ringing was attempted. Execute test port location s.
b. Error Type 23: The circuit pack was logically administered but not physically installed. The
alarm will clear when the circuit pack is installed.
c. Error Type 130: The circuit pack was removed or has been insane for more than
11 minutes. To clear the error, reseat or replace the circuit pack.
Table 99: EMBEDDED AUDIX Analog Line/Control Link Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each
appropriate test’s description, and follow its recommended procedures.
0Any AnyAnytest port location sh r 1
1 (a
) 40977 None
18 0 busyout
station ext
WRN ON release station extension
23 (b
)0 None WRN OFF
130
(c
)
None WRN ON test port location sh
257
(d
)
40973 None
513
(e
)
Any None
1025
(f
)
Looparound test
(#161)
MIN
WRN
2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in set options.
ON test port location l r 2
1281 Conference test
(#7)
MIN
WRN
2
ON test port location l r 2
1537 NPE Crosstalk test
(#6)
MIN
WRN
2
ON test port location l r 2