DS1-BD (DS1 Interface Circuit Pack)
Issue 1 June 2005 983
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to the test’s description and follow the recommended procedures.
b. Error Type 1: the circuit pack stopped functioning or is not completely administered. The
alarm is logged approximately 15 minutes after the circuit pack has been removed or 11
minutes after the SAKI test (#53) fails.
To be completely administered, a DS1 circuit pack must:
● Have an entry in the circuit plan field in change circuit-packs
● Be administered using add ds1 location
● Be physically inserted in the correct slot
2306 Any Yellow Alarm
Inquiry test (#141)
MIN OFF test board location
2561 Any Major Alarm
Inquiry test (#142)
MIN
WRN
†
OFF test board location
2817 Minor Alarm
Inquiry test (#143)
MIN
WRN
†
OFF test board location
3073 to
3160 (s
)
Any Slip Alarm Inquiry
test (#144)
MIN
WRN
†
OFF test board location r 6
3329 to
3345 (t
)
Any Misframe Alarm
Inquiry test (#145)
MIN
WRN
†
OFF test board location r 6
3840 (u
) Any None
3900 (v
) Any CPE Loopback
Jack test (#1212)
3901(w
) Any Far CSU
Loopback test
(#1213)
3902 (x
) Any One-Way Span
test (#1214)
3999 (y
) Any None
Table 338: DS1 Interface Circuit Pack Maintenance Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
4 of 4