Communication Manager Maintenance-Object Repair Procedures
706 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Receive FIFO Overflow Error Counter Test (#625)
This test reads and clears the BRI port’s Receive FIFO Overflow error counter maintained on
the BRI-LINE circuit pack. This counter is incremented by the circuit pack when it detects an
overflow of its receive buffers. The test passes if the value of the counter is 0 (that is, the error
is cleared). If the counter is non-zero, the test fails, and the value of the counter is displayed in
the Error Code field.
This error can occur if signaling frames are being received from the packet bus at a rate
sufficient to overflow the receive buffers on the circuit pack for a port OR if a hardware fault is
causing the receive buffers not to be emptied properly by the circuit pack. This test is useful for
verifying the repair of the problem.
Table 238: Test #625 Receive FIFO Overflow Error Counter Test
Error
Code
Test
Result
Description / Recommendation
2000 ABRT Response to the test was not received from the circuit pack within the
allowable time period.
1. If the test aborts repeatedly up to five times, reset the circuit pack via
busyout board location and reset board location.
2. If the test aborts again, replace the circuit pack.
2012 ABRT Internal system error.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, escalate the problem.
value FAIL The BRI-LINE circuit pack is still detecting errors of this type. The Error
Code field contains the value of this counter.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, run the long test sequence, and pay
particular attention to the Loop Around tests (#618 and #619). See the
repair procedures for the executed test if it fails. Otherwise, go to the
next step.
3. Replace the circuit pack.
PASS The Receive FIFO Overflow error counter was read correctly and has a
value of 0.