TSC-ADM (Administered Temporary Signaling Connections)
Issue 1 June 2005 2365
The two maintenance commands for ADM TSCs are as follows:
test tsc-administered signaling-group-number [/tsc-index]
status tsc-administered signaling-group-number [/tsc-index]
Error Log Entries and Test to Clear Values
Note:
a. Error Types 3840 - 3967: there is no Test to Clear Value for these Error Types which
provide the following additional data that may prove useful when tracking down problems.
Any of these errors indicates that a TSC Heartbeat Inquiry test was run on an active far-end
Administered TSC from the switch. Upon receiving the heartbeat message, the network
communicated that the call was unable to complete. As a result, the error was logged.
1. Check the signaling group status of the D channel or D-channel pair using status
signaling-group grp# for the Administered TSC.
2. Check the status of the Administered TSC using status tsc-administered.
3. Also check the administration of the Administered TSC on the switch.
This error may only be affecting service for some DCS customers. Upon receipt of this error
condition, the switch will tear down and re-establish the ADM TSC within 20 minutes.
The Port field in the error log contains the signaling group number for TSC-ADM errors.
System Technician-Demanded Tests:
Descriptions and Error Codes
Table 847: ADM TSC Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
3840-
3967 (a
)
tsc index # test tsc-administered
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
TSC Heartbeat Inquiry test (#604) Nondestructive