Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
914 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1006 ABRT The port is out of service, perhaps busied out.
1. Use display port location to determine the trunk group/member
number of the port. Use status trunk to determine the service state
of the port. If the port is out of service, wait until the port is in service
and idle before testing.
2. If the port status is in service and idle, then retry the command at
1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run the test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS This test passed. Translation information was successfully updated on the
circuit pack or media module.
1. If signaling troubles are reported (Error Types 1, 257, or 513), verify
translation for this port.
2. Refer problem to the CO.
If the trunk is busied out, the test does not run, but returns PASS. To verify
that the trunk is in-service:
1. Enter status-command to verify that the trunk is in-service. If the
trunk is in-service, no further action is necessary. If the trunk is
out-of-service, continue to Step 2.
2. Enter release-trunk to put trunk back into in-service.
3. Retry the test command.
0
NO
BOARD
The test could not relate the internal ID to the port.
1. Verify that the board’s translations are correct. Translate the board if
necessary.
2. Enter busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location
This should re-establish the linkage between the internal ID and the
port.
Table 311: Test #36 Port Audit Update Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2