UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 June 2005 2453
1015 ABRT Ports on the UDS1 Interface circuit pack have not been busied out to
out-of-service.
1. Enter busyout board location to put each trunk or port of the
UDS1 Interface circuit pack into the out-of-service state.
2. Retry the command.
1039 ABRT The UDS1 Interface circuit pack is providing timing for the system.
Executing this test could cause major system disruption.
If the UDS1 Interface circuit pack needs to be tested, set the
synchronization reference to another DS1 Interface circuit pack or to the
IPSI or Tone-Clock circuit pack via the following command sequence:
1. Enter disable synchronization-switch.
2. Enter set synchronization location.
3. Enter enable synchronization-switch.
Rerun the test. If the test aborts again, a different ABRT code will be
generated. Follow the recommended maintenance procedures for the Error
Code.
1950 ABRT Another loopback/span test is already executing on the DS1 board or the
board is in a network-requested loop-back mode (line loopback or payload
loopback). The hardware error log will indicate whether a Customer
Loop-Back Jack test, Far CSU Loopback test, or the One-Way Span test is
executing or if the board is in line-loopback or payload-loop-back mode.
Only one long-duration loopback/span tests can be active at a given time.
Thus, if a loopback/span test is already active, that test must be terminated
using test ds1-loop location end-loopback/span-test in
order to execute this test.
1951 ABRT The CSU Repeater Loopback test could not be executed because the
120A1 CSU module or the 401A T1 sync splitter was not physically
installed. Physically connect the 120A1 CSU module or the 401A T1 sync
splitter to the UDS1 board on the back of the port carrier.
Table 869: Test #1211 CSU Repeater Loop-Back Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 4