AN-LN-PT (Analog Line Port)
Issue 1 June 2005 427
Error log entries and test to clear values
Notes:
a. Error type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
b. Error Type 1: these are inline errors and can only be resolved over time.
● Aux Data 40960 indicates that too many simultaneous incoming ringing attempts were
made on this board. Only 4 ports on a board may ring simultaneously. A 5
th
incoming
call causes an inline error from the board.
Table 125: Analog line port error log entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/
Off
Board
Test to Clear Value
0 (a
) 0 Any Any Any test port location sh r 1
1 (b
) 40960
40975
40977
none
15 (c
) Any Audits and Updates test (#36)
18 0 busy station extension WRN ON release station extension
130 (d
) None WRN ON test port location sh
257 (e
) 40973 None
513 (f
) Station Present test (#48) WRN OFF test port location sh r 2
769 Battery Feed test (#35) MIN
WRN
1
1. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in set
options.
ON test port location sh r 2
1025 Looparound test (#161) MIN
WRN2
ON test port location l r 2
1281 Conference test (#7) MIN
WRN2
ON test port location l r 2
1537 NPE Crosstalk test (#6) MIN
WRN2
ON test port location l r 2