Communication Manager Maintenance-Object Repair Procedures
2056 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 1: the SNI may have trouble communicating with every other SNI and SNC
circuit pack in the switch node carrier.
1. Replace the SNI circuit pack.
c. Failure audit (#777):The first time you see an SNI-BD error in the error log, run test
board location. If the failure audit test (#777) fails, enter display errors for this SNI
circuit pack and continue with the repair procedures for SNI-BD errors.
125 (e
)None MINON
257 (f
) Any Failure audit (#777)
(c
)
MAJ
MIN
WRN
OFF test board location r 1
513 (g
) Any Failure audit (#777)
(c
)
MAJ
MIN
WRN
OFF test board location r 1
769 (h
) Any Failure audit (#777)
(c
)
MAJ
MIN
WRN
OFF test board location r 1
1025 (i
) Any Failure audit (#777)
(c)
MAJ
MIN
WRN
ON/ OFF test board location r 1
1281 (j
) Any Failure audit (#777)
(c
)
MAJ
MIN
WRN
ON test board location r 1
1537 (k
) Any Failure audit (#777)
(c
)
MAJ
MIN
WRN
OFF test board location r 1
2561 (l
) Any Failure audit (#777)
(c)
MAJ
MIN
WRN
ON test board location r 1
2817 (m
) Any Failure audit (#777)
(c
)
MAJ
MIN
WRN
ON test board location r 1
Table 748: SNI Board Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2