Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
DIOD-TRK (DIOD Trunk)
Issue 1 June 2005 967
e. Error Type 2817 Aux Data 57393 is an in-line error that has no specific test associated with
it. CO released the trunk at least four minutes after the PBX dropped the call. This error
code is log only and causes no other testing to occur. No alarm is generated. Check for
other errors.
f. Error Type 3073 Aux Data 57376 is an in-line error that has no specific test associated with
it. No loop current on incoming call. The incoming destination has already answered and no
loop current has been detected. If this is a hard fault, the Dial Tone test (#0) and every
outgoing call should also fail. Check for other errors.
g. Error Type 3585 Aux Data 57424 is an in-line error that has no specific test associated with
it. No loop current on outgoing call. This error occurs on an attempt to seize a loop or
ground-start trunk for an outgoing call. An error occurs if loop current is not detected or the
caller hangs up before it is detected. Busyout the affected port, and run a Long test. If the
Dial Tone test (#0) passes, ignore this error. Release the port.
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order they are presented. By clearing error codes associated with NPE
Crosstalk test, you may also clear errors generated from other tests in the sequence.
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
NPE Crosstalk test (#6)
S8300 / G700 This test aborts with Error Code 1412.
XND
Dial Tone test (#0)
S8300 / G700 This test aborts with Error Code 1412.
XND
Looparound and Conference test (#33)
S8300 / G700 This test aborts with Error Code 1412.
XND
Audit Update test (#36) X X ND