Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
1246 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
EXT-DEV ADMIN? Y (External Device Alarm)
S8700 | 8710 / S8500
Note:
Note: Use this MO when the External Device Alarm Admin field on the change
system-parameters customer-options screen is y. You must have INADS
or INIT login permissions to administer EXT-DEV Alarm.
S8700 | 8710 / S8500
Each PN’s Maintenance circuit pack has two alarm ports that connect to such external devices
as uninterruptible power supplies (UPSs) or adjuncts (e.g., AUDIX).
Certain conditions on the external device close the contacts on the alarm leads to notify the
switch that in turn originates an EXT-DEV alarm. One set of leads generates a major alarm; the
other set generates a minor alarm.
The special locations UUmajor and UUminor are used to designate the major or minor
Maintenance board’s alarm connection for cabinet UU. The major/minor designation specifies
the port, not the alarm level associated with the connection; for example, the “major” port can be
administered as a major, minor, or warning alarm, and the “minor” port can be administered as a
major, minor, or warning alarm. In addition Analog line ports can also be administered as
external device alarms.
Note:
Note: An un-administered Maintenance board’s external device alarm port, that is
sensing a contact closure will have an entry in the Error Log and in the Alarm
Log. The alarm receiver will not receive warning alarms.
MO Name in
Alarm Log
Alarm
Level
Initial SAT Command to Run
1
1. UU is a cabinet number determined in the Port field of the Alarm or Error Log.
Full Name of MO
EXT-DEV MAJ test eda-external-device-alrm UU External Device Alarm
EXT-DEV MIN test eda-external-device-alrm UU External Device Alarm
EXT-DEV WRN test eda-external-device-alrm UU External Device Alarm