Communication Manager Maintenance-Object Repair Procedures
2028 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
FAIL If this test fails, one or more administered circuit packs in this switch node
carrier did not respond with a “board insertion” uplink message. Use list
config carrier location to verify that the administered SNI and
SNC boards match the physically installed SNI and SNC boards. The
output shows NO BOARD for every board that is administered, but not
inserted.
1. If every administered board is inserted, run this test again.
2. If administration does not match the physical configuration, and is
correct, insert the missing circuit packs in this switch node carrier.
3. If none of the administered boards in this switch node carrier were
inserted, fix any other SN-CONF errors by following the repair
procedures for SN-CONF. Use display errors pnc to view
SN-CONF errors. Next check if any INLs, LNLs, or RNLs are down,
see SYS-LINK (System Links)
on page 2175 for fixing link problems.
PASS If this test passes, every administered circuit pack in this switch node
carrier was inserted.
0NO
BOARD
No board was detected by the test.
1. Check that SNC board is properly translated and inserted.
2. Run the test again. If it fails, reset the board. An SNC should be reset
instead of reseating the circuit pack. The reset board command
should almost never be used on an SNC. It may be necessary to use
reset board if the SNC circuit pack gets into a mode where it
cannot communicate with software. If an SNC with active errors and
alarms is reset, the errors and alarms may take a while to come back,
therefore reset board can mask real problems.
3. Run the test again. If it fails, the ID chip on board may be bad.
Replace the board and retest.
Table 740: TEST #760 Processor Route Audit Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 3