Communication Manager Maintenance-Object Repair Procedures
1690 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1180 ABRT A Maintenance/Test board’s digital port could not be allocated for this test.
Since this error more closely relates to the digital ports on the specific
Maintenance/Test board used than to the TN758 Pooled Modem circuit
pack itself, any hardware testing or replacement activities will focus on
the Maintenance/Test board.
1. Use list config to verify the presence of both digital ports (ports
02 and 03) on the Maintenance/Test board. The display should show
entries for both.
2. If the ports are absent, see M/T-BD (Maintenance/Test Circuit
Pack) on page 1705.
3. If the ports are present, retry the command at 1-minute intervals up to
5 times.
1181 ABRT No time-slots available to connect digital ports for the test.
1. Retry the command at 1-minute intervals up to 5 times.
1182 ABRT Internal system error. Failed to connect the digital ports with time-slots.
1. Retry the command at 1-minute intervals up to 5 times.
1340 ABRT No Maintenance/Test digital port is currently available to perform this test.
1. Use list config to determine whether any Maintenance/Test
digital ports (ports 02 and 03 on the Maintenance/Test circuit pack)
are present in the system. Because at least one Maintenance/Test
circuit pack must always be present in the a PN of any Multi-Connect
configuration, there should be at least two such ports present. If the
ports are present, proceed to step 2. Otherwise, determine why no
ports appear in the list config display.
2. If the ports are present and no errors are logged against them, retry
the command at 1-minute intervals up to 5 times.
3. If the test continues to abort, replace the Maintenance/Test circuit
pack.
2004 ABRT Off-Hook was not received from the Pooled Modem.
1. Busyout the digital port being tested on the Pooled Modem circuit
pack. Retry the command at 1-minute intervals up to 5 times.
2. If the test still aborts, replace the circuit pack.
Table 624: Test #98 Modem Pool Conversion Resource Loop-Around Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 6