M/T-ANL (Maintenance/Test Analog Port)
Issue 1 June 2005 1701
1000 ABRT The port is in use on a valid ATMS test call.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to abort and the port is idle on a valid ATMS test
call, escalate the problem. To determine whether the port is in use by
an ATMS test call, enter status station ext where ext is the
assigned ATMS station’s number.
1001 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions, or it may have time slots out-of-service due
to TDM-BUS errors. A system is considered under heavy traffic when the
Call Processing Occupancy is greater than 50% or when the System
Management and the Call Processing Occupancies together exceed 65%.
To view the system occupancy measurements enter status health on
the system technician terminal.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals up to 3 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present, or some tone
detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up
to 3 times.
1004 ABRT The port was seized by a valid ATMS test call.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to abort and the port is idle on a valid ATMS test
call, escalate the problem. To determine whether the port is in use by
an ATMS test call enter status station ext, where ext is the
assigned ATMS station’s number.