Communication Manager Maintenance-Object Repair Procedures
882 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Notes:
a. See EMG-XFER (Emergency Transfer)
on page 1134 for a description.
b. See EXT-DEV ADMIN? Y (External Device Alarm)
on page 1246 for a description.
c. See RING-GEN (Analog Ring Generator)
on page 1942 for a description.
Single-Carrier Cabinet Power Query Test (#79)
This test queries an PN’s Maintenance circuit pack about the power’s status in a single-carrier
cabinet PN. This test can only detect power problems in the carriers of the PN where the Carrier
Port Power Supply physically resides.
Table 302: Test #79 Single-Carrier Cabinet Power Query Test
Error
Code
Test
Result
Description / Recommendation
1000 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to ABORT with a 2000 error code, check for and
resolve every MAINT (Maintenance circuit pack) error. Repeat the test.
3. If the test still aborts with this error code, escalate the problem.
2029
2319
2320
2500
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1 of 2