Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
438 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1004 ABRT A valid call seized the port during the test and aborted the test.
1. Use display port location to determine the station extension.
2. Use status station extension to determine the service state of
the port.
3. If the port is active, wait until it is idle before testing. Retry the
command at 1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
1005 ABRT This test was aborted due to a configuration problem. The test is not
applicable for this type of analog port. This error can be ignored.
1006 ABRT The port is out-of-service. The busy station extension has been
given to this port. If the port is on a circuit pack, it may have been taken
out-of-service by the failure of the NPE Crosstalk test.
1. Look for error type 18 (port busied out) for this port. If this error is
present, release the port with release station extension, and
run the test again.
2. If the port is on a circuit pack, check for error type 1537 (NPE
Crosstalk test failed) for this port. If this error is present, investigate
the errors associated with the NPE Crosstalk test (#6).
3. Make sure that the terminal is connected and in service, and then
retest.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
Table 129: Test #36 Station Status and Translation Audit and Update (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3