Communication Manager Maintenance-Object Repair Procedures
368 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Conference Circuit Test (#7)
This test verifies that the NPE channel for the port being tested can correctly perform the
conferencing function.
Table 101: Test #7 Conference Circuit Test
Error
Code
Test
Result
Description / Recommendation
ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run test are not available. The port may be
busy with a valid call.
1. Use display port location to determine the station extension.
Use status station to determine the service state of the port. If the
port is active, wait until it is idle before retesting.
2. Retry the command at 1-minute intervals up to 5 times.
1004 ABRT The port was seized by a valid call during the test. The test has been
aborted.
1. Use display port location to determine the station extension.
Use status station to determine the service state of the port. If the
port is active, wait until it is idle before testing.
2. Retry the command at 1-minute intervals up to 5 times.
1018 ABRT Test disabled by administration. This only applies to analog stations.
1. To enable the test for the analog station being tested, enter change
station extension and enter y in the Test field.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any FAIL The NPE of the tested port did not conference the tones correctly. This
causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port can correctly conference multiple connections. User-reported
troubles on this port should be investigated by using other port tests and by
examining station, trunk, or external wiring.