2006 ABRT Indicates that the active Tone-Clock circuit pack or a Tone Detector circuit
pack may not be functioning properly.
If there is more than one Tone Detector circuit pack in the system, then
the problem can be either with the Tone-Clock circuit pack or the Tone
Detector circuit pack. This could also be caused by the mode
administered for the system not matching that of the Tone Detector circuit
pack.
1. Test the active Tone-Clock circuit pack in the PN with test
tone-clock UUC. See TONE-BD (Tone-Clock Circuit)
on
page 2327 for failures.
2. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1-3 FAIL DTMF digits were not detected correctly. This may or may not impact
reception of R2-MFC calls.
1. Run the short test sequence via test port location sh r 1.
2. If the problem persists, the system is still operating properly but
capacity will be reduced. To restore performance to normal, replace
the call classifier circuit pack containing the defective CLSFY-PT (Call
Classifier Port).
S8700 |
8710
S8500
102
FAIL 2225-Hz Modem Answer tone was not detected correctly. This will impact
call-classification operation.
1. Run the short test sequence with test port location sh r 1.
2. If the problem persists, the system can still operate properly but
capacity will be reduced. In order to restore performance to normal,
replace the call classifier circuit pack containing the defective port.
101-
122
130
FAIL Forward or backward R2-MFC signals were not correctly generated or
detected. This will impact R2-MFC calls.
1. Run the short test sequence with test port location sh r 1.
2. If the problem persists, the system can still operate properly but
capacity will be reduced. In order to restore performance to normal,
replace the call classifier circuit pack containing the defective port.
PASS Tone detection verification is successful. The call classifier port is able to
detect and generate every necessary tone.