PRI-CDR (Call Detail Recording Link)
Issue 1 June 2005 1909
Link Tear Down Test (#213)
This test is destructive.
This test disconnects the existing link between the system and the external CDR output device.
If the link has already been disconnected, the test returns PASS. Every resource allocated for a
CDR link is released after this test.
Table 698: Test #213 Link Tear Down Test
Error
Code
Test
Result
Description / Recommendation
40 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
50 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
1010 ABRT The CDR link has been busied out to out-of-service.
1. Enter the release cdr-link primary | secondary
command to release the CDR link from busyout state.
2. Retry the test cdr-link primary | secondary long
command to execute the test.
2012 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS The CDR link is torn down.