Communication Manager Maintenance-Object Repair Procedures
1218 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Any FAIL The EI circuit pack responded incorrectly or if it is the PN active EI circuit
pack, it could not talk to PN circuit packs.
1. If the active EI circuit pack in the PN is failing and duplicated PNC is
enabled, attempt to switch to the standby PNC using reset PNC
interchange.
2. Repeat the short test sequence.
3. If test continues to fail, reset the EI circuit pack via reset board
location.
4. If the EI circuit pack in the PN is failing, enter display errors and
display alarms, and resolve any TDM-CLK, TONE-BD, or SYNC
alarms or errors.
5. Repeat the short test sequence.
6. If test continues to fail, replace the circuit pack or transceiver.
PASS The EI circuit pack did respond correctly to test. Communication from
software to the EI circuit pack is functioning.
1. Refer to other EI circuit pack tests if the link is not functioning
correctly.
0
NO
BOARD
No board was detected by the test.
1. Resolve either wrong board (Error 125) or no board (Error 131)
issues.
2. Check that the board is properly translated and inserted. If so, check
for hyperactivity (Error 1538). If hyperactive, use reset board
location.
3. Run the test again. If it fails, the ID chip on board may be bad.
Replace the board and retest.
Table 414: Test #316 Expansion Interface Control Channel Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2