Communication Manager Maintenance-Object Repair Procedures
1918 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
RANL-STA (Remote Analog Line (Station) Port)
S8700 | 8710 / S8500
A per-port instance of this MO (RANL-STA) is used to maintain the circuitry associated with a
port which has been translated as analog station. The combo blade circuit board has the
capability of having two instances of this type of MO.
Failures of the neon message waiting lamp power and the common ringing application circuitry
are reported as part of common port circuit pack errors; see errors 1281 and 1793 in XXX-BD
(Common Port Circuit Pack/Media Module) on page 2539.
Ringing Caused by Maintenance Testing
Test #48 may cause some terminal equipment to ring briefly during daily maintenance. If this
ringing disturbs the customer or the terminal equipment, disable it in the Tests field of the
change station extension screen. This also disables Test 35 on that station.
Error Log Entries and Test to Clear Values
MO Name in
Alarm Log
Alarm
Level
Initial SAT Command to Run Full Name of MO
RANL-STA MIN test port location l Remote Analog Line Port
RANL-STA WRN test port location sh Remote Analog Line Port
Table 704: Analog Line Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a
) 0 Any Any Any test port location sh r 1
1 (b
) 40960
40975
40977
none
15 (c
) Any Audits and
Updates test
(#36)
1 of 2