Communication Manager Maintenance-Object Repair Procedures
1580 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
0NO
BOARD
The test could not relate the internal ID to the port. This could be due to
incorrect translations, no board is inserted, an incorrect board is inserted,
or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use list
config and resolve any problems that are found.
2. If the board was found to be inserted correctly, enter busyout board
location.
3. Enter the reset board location command.
4. Enter the release board location command.
5. Enter test board location long.
This should re-establish the linkage between the internal ID and the port. If
this is not the case, check to ensure that there is a valid board inserted.
Table 584: Test #62 MET Line Ringer Update Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2